As illustrated with the transformer equivalent circuit, transformers have numerous parasitic properties, which can have a negative effect on the signal. In this chapter it is therefore explained why and where one applies transformers. An additional section deals with the requirements for signal transformers. To conclude the chapter, some standard commercially available transformers are described.
3.1 Function and application areas of transformers
As a result of their functionality, transformers can be used for various tasks:
- Isolation: Transformers are constructed of several windings. Depend ing on the additional isolation, various potentials can be separated or isolated from one another
- Voltage transformation: Voltages are transformed proportionally to the turns ratio
- Current transformation: Currents are transformed inversely to the turns ratio (see chapter I/1.9)
- Impedance matching: Impedances are transformed as the square of the turns ratio
This gives rise to various applications for transformers:
- Voltage (power) supplies: Here the main functions of the trans former are voltage transformation and isolation
- Current converters: Here the main function is to convert high currents into small measurable currents
- Pulse transformers, e.g. drive transformers for transistors: The main function is isolation; sometimes higher voltages are also required to drive a transistor
- Data transformers: Here the main function is also isolation. In addition, sometimes different impedances have to be matched or voltages increased.
3.2 Requirements for data and signal transformers
Transformers are used on data lines mainly for isolation and impedance matching. The signal should be largely unaffected in this case. From chapter I/1.9 we know that the magnetizing current is not transferred to the secondary side. For this reason, the transformer should have the highest possible main inductance.
The signal profiles are usually rectangular pulses, i.e. they include a large number of harmonics. For the transformer, this means that its transformation properties should be as constant as possible up to high frequencies. Taking a look at the transformer equivalent circuit (chapter I/2.3, page 81 ff), it is apparent that the leakage inductances contribute to addition frequency-dependent signal attenuation. The leakage inductances should therefore be kept as low as possible. Signal transformers therefore usually deploy ring cores with high permeability. The windings are at least bifilar; wound with twisted wires is better still. Because the power transfer is rather small, DCR is of minor importance.
The direct parameters, such as leakage inductance, interwinding capacitance etc. are usually not specified in the datasheets for signal transformers, but rather the associated parameters, such as insertion loss, return loss, etc.
The most important parameters are defined as follows:
โข Insertion loss IL: Measure of the losses caused by the transformer
Uo = output voltage; Ui = input voltage
โข Return loss RL: Measure of the energy reflected back from the transformer due to imperfect impedance matching
ZS = source impedance; ZL = load impedance
โข Common Mode Rejection: Measure of the suppression of DC interference
โข Total harmonic distortion: The relationship between the total energy of the harmonics and the energy of the fundamental
โข Bandwidth: Frequency range in which the insertion loss is lower than 3 dB
3.3 A transformerโs effect on return loss Return loss
Return loss is an expression in decibels (dB) of the power reflected on a transmission line from a mismatched load in relationship to the power of the transmitted incident signal. The reflected signal disrupts the desired signal and if severe enough will cause data transmission errors in data lines or degradation in sound quality on voice circuits.
The equation for calculating return loss in terms of characteristic complex line impedance, ZO, and the actual complex load, ZL, is shown below:
Expanding the return loss equation to terms of resistance and reactance we have this formula:
Since return loss is a function of line and load impedance, the characteristic impedance of a transformer, inductor or choke will affect the return loss. A simple impedance sweep of a magnetic component reveals that the impedance varies over frequency, hence the return loss varies over frequency. We will discuss further the effects of a transformer on return loss later. Now letโs explore the relationship of return loss to other common reflection terms.
Reflection Coefficient
While return loss is generally used to denote line reflections in the magnetics industry; a more common term in the electronics industry for reflections is the complex reflection coefficient, gamma, which is symbolized either by the Roman character G or more commonly the equivalent Greek character ฮ (gamma). The complex reflection coefficient ฮ has a magnitude portion called ฯ (rho) and a phase angle portion ฮฆ (Phi). Those of you familiar with the Smith Chart know that the radius of the circle encompassing the Smith Chart is rho equal to one.
The reflection coefficient, gamma, is defined as the ratio of the reflected voltage signal in relationship to the incident voltage signal. The equation for gamma is below:
Keep in mind that just as impedance is a complex number, so is gamma and it may be expressed either in polar format with rho and Phi or in rectangular format:
Return loss expressed in terms of gamma is shown in the equation below:
Standing wave ratio
The reflections on a transmission line caused by impedance mismatches reveal themselves in an envelope of the combined incident and reflected wave forms. The standing wave ratio, SWR, is the ratio of the maximum value of the resulting RF envelope EMAX to the minimum value EMIN.
Fig. 2.63: Standing wave ratio
The standing wave ratio expressed in terms of the reflection coefficient is shown below:
Transmission loss
The last signal reflection expression that we will discuss is the transmission loss. Transmission loss is simply the ratio of power transmitted to the load relative to the incident signal power. Transmission loss in a lossless network expressed in terms of the reflection coefficient is shown below:
Donโt forget that the magnitude of gamma (|ฮ|) is rho (ฯ) and either form can be found in publications and documents regarding reflections.
Related terms
Reviewing the complex reflection coefficient formula we can see that the closer matched the load impedance ZL is to the characteristic line impedance ZO the closer to zero the reflection coefficient is. As the mismatch between the two impedances increase the reflection coefficient increases to a maximum magnitude of one.
The table below shows how the varying complex reflection coefficient relates to SWR, return loss and transmitted loss. As can be seen a perfect match results in SWR equal to 1 and an infinite return loss. Similarly an open or short at the load will result in return an infinite SWR and 0 dB of return loss.
Tab. 2.32: Relationship between reflection coefficient โ standing wave ratio
Plotted on a Smith Chart the relationship is even more evident as constant values of all four parameters are graphed on the chart as circles.
Fig. 2.64: Smith chart
Maximum power transfer
Maximum power transfer is obtained from the source to the load when the source impedance is equal to the complex conjugate of the load impedance. This not only maximizes power but minimizes reflection energy back to the source.
Fig. 2.65: Complex source and load
Return loss with matched load
Letโs take an example of a matched line and load. Letโs say that ZO = 100 โฆ in an ADSL application and that it is terminated with a purely resistive load of 100 โฆ.
Fig. 2.66: Return loss
where:
ZO = 100 + 0j โฆ; ZL = 100 + 0j โฆ
Since the load and source are purely resistive, the return loss will be the same at any frequency. Substituting and calculating shows that RL = โ.
Return loss with unmatched load
Letโs take the same example of an ideal transformer, but with a slightly unmatched load. Letโs say that ZO = 100+0j โฆ as before, but now we will calculate return loss at a number of purely resistive load impedances to show how return loss if affected by mismatch. The resistive load is used again so that the return loss will be independent of frequency.
Tab. 2.33: Return loss at mismatching
The results show that return loss is a function of mismatch and without regard to which direction the mismatch is in. If we look at the case of a slightly mismatched line versus load we see that it is independent of frequency if the line and load are purely resistive. Also note that if the match was perfect, the return loss would be infinite.
Fig. 2.67: Return loss
Return loss with nearly ideal transformer
Now letโs take the same example of a matched line and load, but add in a 1 : 1 transformer which is ideal except for having a primary inductance of LP = 600 ยตH. Again we assume the line impedance is a purely resistive 100 โฆ as well as the load impedance.
When we had an ideal transformer with both line and load impedances purely resistive, our return loss did not vary over frequency and was the same at any frequency. Now however, the inductance will vary over frequency thereby causing the effective load to vary over frequency. The return loss calculation also becomes more complex due to the load impedance now being complex.
Rather than go through all of the complex impedance calculations, I will show the steps required to calculate the return loss.
Step 1: Using impedance transformation calculations, transform the impedance to the same side of the ideal transformer as the primary inductance. In this case the ideal transformer is a 1 : 1 transformer and the load does not change.
Fig. 2.68: Transformer Return loss
Step 2: Combine the XL the current ZL = RL+0j with a resultant ZLโ which is complex.
Fig. 2.69: Return loss with impedance ZLโ
Step 3: Calculate return loss using the resultant load and the original resistive line impedance.
Results: Looking at the results over frequency we can see that the inductance at the lower end is mismatched due the inductance shorting out the load. The lower the primary inductance the more the load will be shunted. Looking at the graphed results we see that return loss due to the primary inductance will behave much like a filter in that it has a knee which will vary with inductance and the slope after the knee is 20 dB per decade.
Tab. 2.34: Return loss with 600 ยตH Lpri at an ideal transformer
Fig. 2.70: Return loss with 600 ยตH Lpri
Return loss with leakage inductance added
Fig. 2.71: Return loss with leakage inductance
Now letโs add leakage inductance of 1 ยตH to the same transformer under the same load conditions. The effective load is calculated in the same manner with ZLโ the reactance of the primary in parallel with the load impedance after transformation. The ZLโโ is ZLโ with the series leakage inductance reactance added to it.
Fig. 2.72: Return loss with leakage inductance and ZLโ
Using the same return loss formula we can then calculate our return loss at various frequencies. From the graphed results we see that the high frequency return loss is affected by the leakage inductance
Tab. 2.35: Return loss with 600 ยตH Lpri at a leakage inductance of 1 ยตH
Fig. 2.73: Return loss with 600 ยตH Lpri and 1 ยตH leakage inductance
For most transformers the primary and leakage inductances will have the greatest effect on return loss, providing that the turns ratio chosen effectively matches the load resistance to the line impedance.
Return loss with a less-than-ideal transformer
With the linear transformer model that is typically used in low frequency transformer design applications, we can calculate theoretical return loss based on lumped parameter analysis. With the exception of interwinding capacitance, we can reduce the linear transformer model to a load impedance by either combining the elements in parallel or series. Keep in mind that the secondary DC resistance and the ZL have to be transformed by dividing by n2 when brought to the line side of the model.
Fig. 2.74: Return loss of real transformers
Interwinding capacitance can not be so simply modeled because it resides on neither the line nor the load side of the model and can not be transformed into the equivalent load. At low frequencies the interwinding capacitance acts as an open across the transformer and typically can be ignored. In fact most modeling programs for transformers do ignore interwinding capacitance as leakage inductance and primary inductance are the dominant elements. However in certain designs where interwinding capacitance is fairly large and the operating frequencies are high, it can become a very significant factor. Suffice it to say that if interwinding capacitance needs to be included in the model it would be wise to use a more sophisticated analysis program such as LTspice.
Letโs take a look now at the linear transformer model for the theoretical ADSL transformer shown below with a load that is just off of the ideal 25 โฆ for a perfect match. We will take this and model the effect of the various elements looking at it parameter by parameter.
Fig. 2.75: Return loss of ADSL transformer
Return loss effect of DCRs
The return loss effect of the DC resistance in the example below high lights two observations. First of all even though the secondary resistance is lower at 1.5 โฆ in comparison to the primary resistance of 3.0 โฆ, the effect on return loss is much greater. The reason for this is that the 1.5 โฆ secondary when reflected to the primary side of the transformer is seen as 6.0 โฆ.
Also note that a lower return loss number is only slightly affected by other elements that have significantly better return loss when standing alone. The return loss when due only to the secondary resistance is roughly 30 dB while the return loss due to the primary resistance is roughly 37 dB. When combined, the net effect is a return loss of 27 dB.
Fig. 2.76: Return loss
Return loss effect of leakage inductance and distributed capacitance
The effects on return loss by the leakage inductance and the distributive capacitance parameters of a transformer are interesting to compare as well. We see from the example below that the effects due solely to leakage inductance reveal a decaying return loss at the rate of 20 dB per decade. Now taking a look at the distributed capacitance we see that it causes a high-end decay at the same rate with the knee at a higher frequency.
The comparison gets interesting when we looked at the combined affect. When combined the net result is an improvement of return loss. Why is this? If you remember in our previous discussion, the return loss is a function of mismatch without regard to which direction the mismatch is in. With this example the mismatch is in opposite directions so the addition of the distributed capacitance effect actually improves the overall return loss.
Thinking about this in analytical terms, what is happening in the equivalent circuit? The reflected load is being increased by the reactance due to the leakage inductance thereby causing mismatch. However the reactance of the distributed capacitance is in parallel there by reducing the mismatch back toward the optimal 100 โฆ reflected load.
Fig. 2.77: Return Loss with leakage inductance
Return loss effect of interwinding capacitance
As mentioned earlier, the effect of interwinding capacitance is very difficult to calculate using simple equivalent impedance transformations. The problem is that the interwinding capacitance is shared by both windings and is not clearly on one side of the ideal transformer or the other. The impact to the circuit model is therefore not so straight forward and requires more sophisticated modeling techniques. The example below was modeled with PSPICE rather than with simple calculations.
Typically however, the interwinding capacitance has very little effect on the return loss in comparison to the leakage inductance and can be ignored. A word of warning is in order however since cases where leakage inductance is very low while at the same time the interwinding capacitance is very high, interwinding capacitance can become a factor to reckon with.
Fig. 2.78: Return Loss and interwinding capacitance
Return loss effect of resistive core loss and inductance
In this example we compare return loss due to the primary inductance as well as to the resistive core loss assuming that core loss factor, RcAlpha, is equal to 0.44. As can be seen from the return loss due to the combined effect, the resistive core loss has very minimal impact. In very low frequency applications, such as audio, the resistive core loss can be a factor.
Fig. 2.79: Return loss and core loss/L-value
Return loss effect of all parameters
Finally, looking at the effects of all parameters combined we can determine which are the significant factors in a typical transformer application. As can be seen from the results below, the leakage inductance and the primary inductance are the driving factors. While the other parasitic parameters do play a role in shaping the return loss response, they play a relatively minor role in a typical transformer design.
Fig. 2.80: Return loss with all parameters
A closer look at dominating parameters
In closing we take a closer look at the dominating parameters of the transformer. The top graph shows the return loss of various models in comparison to the ideal transformer with the slightly mismatched load. Then the lower graph just zooms in on the non-ideal transformer cases.
Practical tip:
These graphs high-light the fact that primary and leakage inductance are the parameters that typically dictate return loss and that there is justification to ignoring interwinding capacitance in most applications.
Fig. 2.81: Return loss and influence of the dominating parameters Lprim/Lleak
ABC of CLR: Chapter L Inductors
Applications for transformers
EPCI licensed content by: Wรผrth Elektronik eiSos, Trilogy of Magnetics, handbook printouts can be ordered here.
This page content is licensed under a Creative Commons Attribution-Share Alike 4.0 International License.